Opening the lab

Boyle’s Law  / CSEC Physics
PV = constant
All labs
Air trapped above oil in a glass tube with a volume scale, a pressure gauge and an air pump, with a graph that builds from the recorded readings.
Oil
Your readings
Line of best fit, or a reading with a problem
Theory

Set up the gas

Human errors
Readings carry realistic slips, like a real student's
Pressure set by the pump100 kPa
Graph
Air warms when squeezed
The real effect: it takes minutes to settle
Show the theory
Draws what PV = constant predicts
Try this: pump to 200 kPa and record at once, then wait 2 minutes and record again. Then take six or more pressures, wait before each one, and flip the graph between P against V and P against 1/V.
How to answer: read the wording carefully. At constant temperature P × V stays the same, so pressure and volume change in opposite directions.
Pressure, P
100kPa
Volume, V
40.0cm³
Last P × V
–kPa cm³
Since pumping
0:00min:s

Results table

Press Record P and V to take a reading.
Record at least 3 readings first

Working

What the experiment is about

Boyle’s law is about a fixed mass of gas kept at a constant temperature. You trap some air in a glass tube, squeeze it with a pump, and measure its pressure and its volume together. The question is how one changes when you change the other.

The aim in Paper 3 is: to determine the relationship between the pressure and the volume of a fixed mass of gas at constant temperature.

Boyle’s law

For a fixed mass of gas at constant temperature, the pressure is inversely proportional to the volume.

P V = constant

For a gas going from one state to another: P1V1 = P2V2.

Example. A 40 cm³ column of air at 100 kPa is squeezed to 25 cm³. Then P2 = 100 × 40 ÷ 25 = 160 kPa.

The apparatus in this lab

  • A glass tube, sealed at the top, with a volume scale in cm³. The air to be tested is trapped above a column of oil.
  • The oil seals the air in. The meniscus (the curved top of the oil) shows the volume of the air.
  • An air pump pushes on the oil and squeezes the trapped air. A tap keeps the pressure in.
  • A pressure gauge reads the pressure. It reads the absolute pressure, atmosphere included, so it shows 100 kPa before you pump.

This lab is a model. The air obeys P V = 4000 kPa cm³ exactly (40 cm³ at 100 kPa). The warming, the 2 minute settling time and the leak are built in with believable numbers, not measured from a real tube.

The two graphs

  • P against V is a curve that falls and flattens, and never touches either axis. It shows that P goes down as V goes up, but not how.
  • P against 1/V is a straight line through the origin. That is the test that P is inversely proportional to V.
  • The gradient of the P against 1/V line is P × V, the constant. The unit is the unit of P divided by the unit of 1/V: kPa cm³. Here it is about 4000 kPa cm³.
Common CSEC error: writing the unit of the gradient as kPa/cm³. That would be the unit if the x axis were V, but the x axis is 1/V, which is in cm−3.

Must the line pass through the origin?

Yes. P × V is constant, so P = constant × (1/V). P is directly proportional to 1/V, and zero in gives zero out.

So draw your line of best fit through (0, 0), with the points scattered a little either side of it. That scatter is human error, such as reading the meniscus slightly high or low.

If your line misses the origin, something is wrong. The likely cause here is a systematic error in P: a gauge that leaves out the atmosphere makes every pressure too small by the same amount, so the line cuts the P axis below zero.

The method

  • Check that the air is sealed by the oil and that the pump is connected tightly.
  • Read the pressure on the gauge and the volume at the meniscus with the starting air.
  • Pump to a higher pressure and close the tap. Wait 2 to 3 minutes, then read P and V again.
  • Repeat for at least six different pressures.
  • Work out 1/V for each reading, plot P against 1/V, draw the line of best fit and find its gradient.

Why it works, and why you must wait

Gas pressure comes from molecules hitting the walls. Squeeze the same molecules into half the volume and they hit the walls twice as often, so the pressure doubles. That only holds if they keep the same speed, which means the same temperature.

Squeezing air does work on it, so it warms up. Warm air at the same pressure takes up more space, so V reads too big and P × V comes out too high. Heat slowly escapes to the room. In this lab the extra warmth fades with a time constant of 40 s, so after 2 minutes only about 5% of it is left.

Common CSEC error: saying “P and V are inversely proportional because one goes up when the other goes down”. The proof is a straight line through the origin on P against 1/V, or P × V staying constant.

Precautions and sources of error

PrecautionWhy
Air sealed by the oil, pump tightly connectedAir that leaks out changes the mass of gas.
Wait 2 to 3 minutes before each readingThe temperature must come back to room temperature.
Eye level with the meniscusAvoids a parallax error in V.
At least six pairs of readingsGives a reliable line of best fit.
  • Leakage of air from the tube or the joints.
  • The temperature is not constant if you read too soon.
  • The meniscus is hard to read exactly, and the gauge may have a zero error.

Where Paper 3 asks it

His notes list Boyle’s law as set in January 2020, Paper 3, Question 2 and January 2017, Paper 3, Question 2. These questions usually ask you to complete a table (1/V from V), plot P against 1/V, find the gradient with its unit, and give precautions and sources of error. The Paper 3 practice tab walks through each of those.