Current, potential difference and resistance
- Current, I: the rate of flow of charge, measured in amperes (A) with an ammeter.
- Potential difference, V (p.d., or voltage): the energy transferred to each coulomb of charge as it passes through a component, measured in volts (V) with a voltmeter.
- Resistance, R: how hard a component makes it for current to flow, measured in ohms (Ω). It is defined as R = V ÷ I.
One ohm is one volt per ampere: a component has a resistance of 1 Ω if 1 V across it drives a current of 1 A.
Ohm’s law
V = I R
Ohm’s law: the current through a metal conductor is directly proportional to the potential difference across it, provided its temperature stays constant.
| To find | Use |
| p.d. | V = I × R |
| current | I = V ÷ R |
| resistance | R = V ÷ I |
Common CSEC error: writing R = I ÷ V, or R = V × I. Cover the quantity you want in the V, I, R triangle and the rest tells you what to do.
The circuit and the two meters
- The ammeter goes in series, in the same loop as the resistor, so the same current passes through both. A good ammeter has a very small resistance, so it does not change the current it measures.
- The voltmeter goes in parallel, across the two ends of the resistor. A good voltmeter has a very large resistance, so it takes almost no current away.
- The rheostat is a variable resistor in series. Moving its slider changes the current and the p.d. across the resistor, so you can take many pairs of readings. The switch lets you stop the current between readings.
Common CSEC error: putting the voltmeter in series, or the ammeter across the resistor. Both give nonsense readings.
The graph and its gradient
- Plot V on the vertical axis and I on the horizontal axis.
- For a resistor that obeys Ohm’s law the points lie on a straight line through the origin. V is directly proportional to I.
- The gradient = ΔV ÷ ΔI = R, in ohms. Pick two points far apart on the line of best fit, not two of your readings.
- If you plot I against V instead, the gradient is 1 ÷ R. It is still a straight line, but it is not the resistance.
Must the line pass through the origin?
For a resistor that obeys Ohm’s law, V = I R, so V is directly proportional to I and the graph of V against I is a straight line through the origin (0, 0). Zero current gives zero p.d.: when I = 0, V = I R = 0, so the line must start at (0, 0).
Draw your line of best fit from (0, 0), with the points scattered either side of it. That scatter is human error in reading the meters. If your line misses the origin, the most likely cause is a zero error on the voltmeter or the ammeter, which shifts every reading by the same amount. The filament lamp’s curve also starts at (0, 0).
A component that does not obey Ohm’s law
A filament lamp gives a graph of V against I that is a curve getting steeper. Its resistance is not constant: as more current flows, the thin tungsten filament gets very hot, its atoms vibrate more, and they get in the way of the moving electrons more often. So V ÷ I rises as the current rises.
A component like this is called non-ohmic. A metal wire is also non-ohmic if it is allowed to get hot, which is why the temperature must stay constant in Ohm’s law.
The method
- Connect the circuit: supply, switch, rheostat, ammeter and resistor in series, voltmeter across the resistor.
- Close the switch, read the ammeter and the voltmeter, then open the switch.
- Move the rheostat and repeat for at least six pairs of readings, from a small p.d. to a large one.
- Work out R = V ÷ I for each pair, plot V against I, draw the line of best fit and find its gradient.
Precautions and sources of error
| Precaution | Why |
| Read each meter with your eye straight in front of the needle | Reading from the side gives parallax error. |
| Tighten every connection | A loose one has contact resistance and makes the ammeter flicker. |
| Open the switch between readings | A current left on heats the resistor and changes its resistance. |
| Check each meter for a zero error | With the switch open the needle should rest on zero. If not, correct every reading. |
- Estimating where the needle points between two marks.
- Heating of the resistor while the current flows.
- Zero error on a meter.
- A rheostat of too high a resistance only allows tiny currents, which are hard to read accurately.
- Thin connecting wires or a wire that is not the same thickness all along have extra resistance.
Where Paper 3 asks it, and how this lab works
His notes list Ohm’s law as set in May/June 2019 Question 1, January 2019 Question 2, January 2018 Question 2, May/June 2017 Question 1 and May/June 2015 Question 1 of Paper 3. Check the years against the past papers. The Paper 3 practice tab walks through the table, the graph, the gradient, the precautions and the sources of error.
This lab is a model. The resistance of each unknown resistor is set at random from 4.7, 6.8, 10, 15 and 22 Ω with a small tolerance, and the lamp is a calibrated curve. The heating effect is calibrated to be easy to see in five minutes, not measured from a real resistor. The meters have no resistance of their own except for a small 0.2 Ω in the ammeter and leads.